<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="http://spm-wiki.createc.de/skins/common/feed.css?303"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>http://spm-wiki.createc.de/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Zoephel</id>
		<title>SPM-Wiki - User contributions [en]</title>
		<link rel="self" type="application/atom+xml" href="http://spm-wiki.createc.de/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Zoephel"/>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Special:Contributions/Zoephel"/>
		<updated>2026-06-13T10:08:08Z</updated>
		<subtitle>User contributions</subtitle>
		<generator>MediaWiki 1.22.5</generator>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=STMAFM_Main</id>
		<title>STMAFM Main</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=STMAFM_Main"/>
				<updated>2014-09-15T11:01:22Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Main Form ==&lt;br /&gt;
The STMAFM form contains the main control elements of the software. Below the menu bar several control the data acquisition and analysis of the STM data.&lt;br /&gt;
&lt;br /&gt;
To take a new image press the &amp;lt;START&amp;gt; button. To stop press the &amp;lt;STOP&amp;gt; button. When a new scan is started a default filename is assigned to the image. It consists of the date and time, when the scan was started. Its extension will be '.dat'. A single letter is put in the front of the name, which is used to indicate the machine name. (Example:' A020124.190937.dat' ). To save the file either press the &amp;lt;QSAVE&amp;gt; button which saves the file in the current directory, indicated in the status line at the bottom of the window, or use the menu command &amp;lt;Save *.dat&amp;gt; under &amp;lt;File&amp;gt;. As long as the files has not been saved a ' * ' is attached to the file. The &amp;lt;Copy&amp;gt; copies the data in the left image to the second image on the right. &lt;br /&gt;
&lt;br /&gt;
The basic operations to display the data are done using the following buttons:&lt;br /&gt;
&lt;br /&gt;
 &amp;lt;DA&amp;gt;:  Display the image using different line by line subtraction modes &lt;br /&gt;
 &amp;lt;DX&amp;gt;:  Display the image using automatic plane substraction&lt;br /&gt;
 &amp;lt;DP&amp;gt;:  Display the image using plane substraction&lt;br /&gt;
 &amp;lt;LA&amp;gt;:  Display image in DA mode and perform automatic scaling&lt;br /&gt;
 &amp;lt;LP&amp;gt;:  Perform a low pass filter operation&lt;br /&gt;
 &amp;lt;HP&amp;gt;:  Perform a high pass filter operation&lt;br /&gt;
 &amp;lt;Pln&amp;gt;: Input 3 points (with the mouse) to determine the plane for plane background subtraction&lt;br /&gt;
 &amp;lt;Lin&amp;gt;: Calculate a linescan along a line between 2 points&lt;br /&gt;
 &amp;lt;LM&amp;gt;  Lateral manipulation&lt;br /&gt;
 &amp;lt;VM&amp;gt;  Vertical manipulation of I/V spectroscopy&lt;br /&gt;
 &amp;lt;TF&amp;gt;  Tip forming&lt;br /&gt;
&lt;br /&gt;
Use &amp;lt;Disp LinePlan Quad&amp;gt; under &amp;lt;Display&amp;gt; in the menu subtract to perform an automatic line/plane subtraction using also quadratic terms&lt;br /&gt;
Below the buttons you find the Palette window, which displays the current 8bit palette. Use the left mouse button to switch between different standard palettes. Using the right mouse button will open a popup menu with additional options to create a user defined palette or to load and save externally defined palettes.&lt;br /&gt;
&lt;br /&gt;
The small list box on the right is used for communication between different instances of the STMAFM program. If the instance of the program which is in data acquisition mode saves a file then this filename is send to all other instances of the program running in analysis mode.&lt;br /&gt;
&lt;br /&gt;
Below the buttons the screen is separated in two parts, divided by an horizontaly movable slider. On the left is always the image of the current data file displayed. All the operations like scanning and image processing are done in this part on the window. On the right usually a list of all loaded files is displayed. A small icon image and some info is shown for each file. The two modes to display these data are 'Report&amp;quot; and 'Icon' view. The modes can be selected under menu item 'Display'. When in Report view pressing on the 'Image' bar will switch the way how the info is displayed. The list view can be suppressed by selecting 'Image2' under menu item 'Display' and the second image is displayed instead.&lt;br /&gt;
&lt;br /&gt;
On the bottom of the window a status bar is located. It shows the current date and time, some status info about the scanning status, the mouse position on the image,the size of  the image, the current default directory, the available space of disk storage.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[file:clipstmafm.png|600px]]&lt;br /&gt;
&lt;br /&gt;
== Menu Structure ==&lt;br /&gt;
&lt;br /&gt;
'''File'''		                         &lt;br /&gt;
 Open  *.DAT            Open STMAFM DataFile&lt;br /&gt;
 Save  *.DAT            Save STMAFM DataFile&lt;br /&gt;
 QuickSave              Save STMAFM DataFile in active directory&lt;br /&gt;
			&lt;br /&gt;
 Export File		&lt;br /&gt;
 Save  *.BMP         	Save Image as BMP-File&lt;br /&gt;
 Save *.JPG		Save as JPEG File&lt;br /&gt;
 SaveEMF *.EMF           Save Image in EMF Format&lt;br /&gt;
 SaveAscii *.ASC   	Save Image-Data in ASCII Format&lt;br /&gt;
			&lt;br /&gt;
 Import File		&lt;br /&gt;
 Load *.BMP      	Load BMP File&lt;br /&gt;
 Load *.TIF		Load TIF File&lt;br /&gt;
			&lt;br /&gt;
 Print		&lt;br /&gt;
 Print Image             Print the image&lt;br /&gt;
 Print Listview          Print the Filelist in Listview&lt;br /&gt;
 Printer Setup           Select the printer&lt;br /&gt;
			&lt;br /&gt;
 Special		&lt;br /&gt;
 Compress Files		All Files are saved using Data compression with Zlib&lt;br /&gt;
 Save Listview-Files   	Save List of Files in the Listview window&lt;br /&gt;
 Autosave  *.bak       	Save all recorded images&lt;br /&gt;
 AutoSave All		Save all images&lt;br /&gt;
 DOS-CommandLine   	Open a DOS-Window&lt;br /&gt;
 HPData			Get Data from Agilent Datalogger&lt;br /&gt;
 Get_SRS_Lockin_Val	Get External Lockin Setup Parameters&lt;br /&gt;
 &lt;br /&gt;
 STMAFM-Analysis        Start another copy of the STMAFM-Program&lt;br /&gt;
 Exit                   Exit the STMAFM-Program&lt;br /&gt;
 About                  About &lt;br /&gt;
 ReOpen                 Opens the last file&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Edit    &lt;br /&gt;
 Copy Clipbd                Copy the image to the clipboard&lt;br /&gt;
 Copy Dataimage2            Copy left image to the right&lt;br /&gt;
 Copy Clipbd EMF            Copy the image to the clipboard in EMF Format with Info&lt;br /&gt;
 Copy New Window            Copy the image into new form&lt;br /&gt;
 Copy Overview              Copy the image into the overview form&lt;br /&gt;
 Copy Palette to Clipbd     Copy the palette to the Clipboard       &lt;br /&gt;
&lt;br /&gt;
Scan   &lt;br /&gt;
 Scan Start             		Start the Scan&lt;br /&gt;
 Scan Stop              		Stop the Scan&lt;br /&gt;
 Enable/Start RepeatTimer	Start the Repeat-Timer&lt;br /&gt;
 Preamplifier                 	Select the preamplifier&lt;br /&gt;
 Preamp_Femto_LowNoise  		Select for Femto Preamp in Low Noise Mode&lt;br /&gt;
 Preamp_Femto_HighSpeed 		Select for Femto Preamp in High Speed Mode&lt;br /&gt;
 Preamp_Femto_100G		Select for Femto Preamp with fixed gain 10^11&lt;br /&gt;
 Preamp_UserType			Select for User specific Preamp &lt;br /&gt;
&lt;br /&gt;
 Autofilesave			Save every image&lt;br /&gt;
 Autorepeat			Start a new image automatically&lt;br /&gt;
 Autodispreset         		Clear the image window when starting a new scan&lt;br /&gt;
&lt;br /&gt;
 Show Scanline Marker		Display a red line at the actual scan line position&lt;br /&gt;
 Display current Scan Profile	Display the current line as a line scan in a separate window&lt;br /&gt;
 &lt;br /&gt;
 Scan_Y_Direction		Select the Scandirection (Top-Bottom,Bottom-Top,etc)&lt;br /&gt;
 ScanCoarse			Check to set scanning by Coarse Piezos otherwise the main Piezo is used&lt;br /&gt;
&lt;br /&gt;
DSP       &lt;br /&gt;
 Lateral Manip.      		Lateral Manipulation&lt;br /&gt;
 Vertical Manip.            	Vertical Manipulation&lt;br /&gt;
 Tip Forming                	Tip Forming&lt;br /&gt;
&lt;br /&gt;
 SetXYOffset - Top           	Set the xy-offset for the new top site&lt;br /&gt;
 SetXYOffset - Center        	Set the xy-offset for the new center site&lt;br /&gt;
 SetXYOffset - Zoom        	Set the xy-offset for the new center site&lt;br /&gt;
 ResetXYOffset  			Set the xy-offset to (0,0)&lt;br /&gt;
 Copy Offset from Param    	Copy the xy-offset values from the scanparameterlist&lt;br /&gt;
 1: Offsetx,y:  0 0          	Select as new Offset&lt;br /&gt;
 2: Offsetx,y   0 0          	Select as new Offset&lt;br /&gt;
 3: Offsetx,y   0 0          	Select as new Offset&lt;br /&gt;
 4: Offsetx,y   0 0          	Select as new Offset&lt;br /&gt;
 Set_Plan_Dx_Dy			Set the parameters for the plan-offset. &lt;br /&gt;
 Set_DSP_Clock 			Change the Clock-Frequency of the DSP-FeedBack-Loop&lt;br /&gt;
 &lt;br /&gt;
Image   &lt;br /&gt;
 Undo Filter                 	Undo last image operation&lt;br /&gt;
 Filter&lt;br /&gt;
  LowPass                     	Low Pass Filter the image&lt;br /&gt;
  HighPass                    	High Pass Filter the image&lt;br /&gt;
  Laplace                     	Laplace Filter the image&lt;br /&gt;
  Median				Median Filter&lt;br /&gt;
  Edge(Horz)			Edge Filter in the horizontal direction&lt;br /&gt;
  Invert                      	Invert the image&lt;br /&gt;
  Imagedata * 10			The image data is multiplied by a factor of 10&lt;br /&gt;
  Imagedata / 10			The image data is divided by a factor of 10&lt;br /&gt;
&lt;br /&gt;
 Resize&lt;br /&gt;
  Zoom_Up_Rect             	Zoom up a selected rectangle &lt;br /&gt;
  Resize   / 2                	Resize the image&lt;br /&gt;
  Resize   x 2                	Resize the image&lt;br /&gt;
  Interpolation  / 2          	Interpolate the image&lt;br /&gt;
  Interpolation  x 2          	Interpolate the image&lt;br /&gt;
       &lt;br /&gt;
 Rotate90deg&lt;br /&gt;
&lt;br /&gt;
 FFT&lt;br /&gt;
  FFT2D                       	Fast Fourier Transform&lt;br /&gt;
  FFT2D Invers                	Inverse FFT&lt;br /&gt;
  FFT2d Cutout               	Cutout a part of the FFT&lt;br /&gt;
  FFT Evaluate			Open FFT Evaluate window&lt;br /&gt;
&lt;br /&gt;
 Image Analysis&lt;br /&gt;
  Histogram                   	Show the histogram of the image&lt;br /&gt;
  Areacalculation             	Calculate the size of islands&lt;br /&gt;
  Islandsize                  	Calculate the size of islands&lt;br /&gt;
&lt;br /&gt;
Display&lt;br /&gt;
 Zoom&lt;br /&gt;
  100%&lt;br /&gt;
  200%&lt;br /&gt;
  300%&lt;br /&gt;
  400%&lt;br /&gt;
&lt;br /&gt;
 ListView&lt;br /&gt;
  Report				Show files as icons and info&lt;br /&gt;
  Icon				Show files as icons only&lt;br /&gt;
  Image2				Show Image2 and not the Listviewbox&lt;br /&gt;
  ListViewBox enabled      	Enables the ListView Box	&lt;br /&gt;
  AutoclearList                	Clear the Listviewbox before new a new list is added&lt;br /&gt;
  Largeiconsize=64-256   	Icon size of the images in the listviewbox&lt;br /&gt;
  Load Icon Plan              	Load the icons using image plan subtraction&lt;br /&gt;
  Clear Listview			Clear the ListView&lt;br /&gt;
   	&lt;br /&gt;
 DispCommands &lt;br /&gt;
  DispAuto                    	Display image using linear line background subtraction &lt;br /&gt;
  DispPlanAuto                	Display image using auto plan background subtraction &lt;br /&gt;
  DispPlan                    	Display image using plan subtraction&lt;br /&gt;
  Last Disp Autoscale		Display with automatic scaling&lt;br /&gt;
  Plan Auto Subtract		Like Displanauto + subtract plane from image data&lt;br /&gt;
  Linescan                    	Linescan in the image&lt;br /&gt;
  Plan2dinput                 	Input 3 points to select the background subtraction plane&lt;br /&gt;
  Configuration&lt;br /&gt;
   DACunits                    	Select DAC units&lt;br /&gt;
   nm-Units [A]                	Select Angström units&lt;br /&gt;
  Display Image in Lines		Select to display image in line and not gray scale mode&lt;br /&gt;
  Disp LinePlan Quad		Select to perform lin.+quad. Backgroundsubtraction&lt;br /&gt;
  Disp Plan and Subtract	If selected Disp Plan subtracts the plane from the image data&lt;br /&gt;
  Disp Automode Offset/Slope   	DA Mode subtract offset and slope line by line&lt;br /&gt;
  Disp Automode Offset   	DA Mode subtract offset line by line&lt;br /&gt;
  Disp Automode None 		DA Mode subtract offset of first line&lt;br /&gt;
  Disp Automode Diff		DA Mode differentiate image data line by line&lt;br /&gt;
	&lt;br /&gt;
Forms&lt;br /&gt;
 Parameter&lt;br /&gt;
 Lat.Manip            		Show the Latmanip window&lt;br /&gt;
 Vert.Manip           		Show the Vertmanip. window&lt;br /&gt;
 Time Spectrum			Show the Time Spectrum window&lt;br /&gt;
 AFM				Show the AFM PLL window&lt;br /&gt;
 Ramp-Controller			Start Ramp Controller&lt;br /&gt;
 New Channelform			Open another Channelform&lt;br /&gt;
 Linescan            		Show the linescan window&lt;br /&gt;
 Draw Grid			Show Grid window&lt;br /&gt;
 3dView				Show 3d View window	&lt;br /&gt;
 Memo				Show separate Memo window&lt;br /&gt;
 Overview                		Show the overview window&lt;br /&gt;
 Slider				Show the Slider window&lt;br /&gt;
 User Form			Show the User Form&lt;br /&gt;
 Reset Form Positions		Position all windows at (top,left) = (0,0)&lt;br /&gt;
 Show/Hide Old Param 		Show/Hide the old Parameter window&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Debug   &lt;br /&gt;
 Reset Scanstatus            	Enable all buttons again&lt;br /&gt;
 Remote				Open Remote window&lt;br /&gt;
 Client Server Control		Open Client Server Control&lt;br /&gt;
 FIFO_COM USB2.0                Shows whether communication is by USB2.0 Hardware&lt;br /&gt;
 Build Testimage                Build a new image without scanning&lt;br /&gt;
 STM Simulation			Run the STM Programm in Simulation Mode (with DSP) &lt;br /&gt;
 PLL Off                        Switch PLL off&lt;br /&gt;
 Debug Messages On   		Show Debug messages&lt;br /&gt;
 Block Data Transfer		Transfer Data after Acquitstion has been done&lt;br /&gt;
 ADDA DSP Connect		Manually start/stop communication between DSP and ADDA&lt;br /&gt;
 Form Memory Watch		Shows some status data&lt;br /&gt;
       &lt;br /&gt;
&lt;br /&gt;
Tools&lt;br /&gt;
 Tip-Etching			Open to etch STM tips&lt;br /&gt;
 Initialization			Open Initialization window&lt;br /&gt;
 Data Recorder			Open Datarecorder window&lt;br /&gt;
 Flash Utility			Utility to burn Flash on DSP Board with new DSP software&lt;br /&gt;
	&lt;br /&gt;
Help&lt;br /&gt;
 Show STMAFM-Manual		Show STMAFM Manual (PDF)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Main Buttons ==&lt;br /&gt;
&amp;lt;Start&amp;gt;     or 	&amp;lt;F1&amp;gt;:  	Start the scan&lt;br /&gt;
           &lt;br /&gt;
&amp;lt;Stop&amp;gt; 	    or 	&amp;lt;F2&amp;gt;:  	Stop the scan&lt;br /&gt;
&lt;br /&gt;
&amp;lt;Qsave&amp;gt;   or 	&amp;lt;F3&amp;gt;: 	Automatically saves an image in the actual directory&lt;br /&gt;
&lt;br /&gt;
&amp;lt;Copy&amp;gt;     or 	&amp;lt;F4&amp;gt;: 	Copy Image1 to Image2&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LM&amp;gt;        or 	&amp;lt;F5&amp;gt;:	Perform a lateral manipulation&lt;br /&gt;
&lt;br /&gt;
&amp;lt;VM&amp;gt; 	    or 	&amp;lt;F6&amp;gt;:	Perform a vertical manipulation or spectroscopy&lt;br /&gt;
&lt;br /&gt;
&amp;lt;TF&amp;gt; 	    or 	&amp;lt;F8&amp;gt;:	Perform tip forming&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DA&amp;gt; 	    or 	&amp;lt;F9&amp;gt;: 	Display the image with automatic line by line background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DX&amp;gt; 	    or 	&amp;lt;F10&amp;gt;:  Display the image with automatic plane background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DP&amp;gt; 	    or 	&amp;lt;F11&amp;gt;: 	Display the image with planar background subtraction with predefined parameters&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LA&amp;gt;        or  &amp;lt;F12&amp;gt;: Display the image with automatic greyscale scaling&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LP&amp;gt; 	or    &amp;lt;Shift F9&amp;gt;:       Low pass filter&lt;br /&gt;
 &lt;br /&gt;
&amp;lt;HP&amp;gt; 	or   &amp;lt;Shift F10&amp;gt;:	High pass filter&lt;br /&gt;
&lt;br /&gt;
&amp;lt;PLN&amp;gt; 	or   &amp;lt;Shift F11&amp;gt;:	Input 3 points for the plane used in plane background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LIN&amp;gt; 	or   &amp;lt;Shift F12&amp;gt;:	Display a linear scan between two points on the image&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==  ==&lt;br /&gt;
[[category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=STMAFM_Main</id>
		<title>STMAFM Main</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=STMAFM_Main"/>
				<updated>2014-09-15T10:56:23Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Main Form ==&lt;br /&gt;
The STMAFM form contains the main control elements of the software. Below the menu bar several control the data acquisition and analysis of the STM data.&lt;br /&gt;
&lt;br /&gt;
To take a new image press the &amp;lt;START&amp;gt; button. To stop press the &amp;lt;STOP&amp;gt; button. When a new scan is started a default filename is assigned to the image. It consists of the date and time, when the scan was started. Its extension will be '.dat'. A single letter is put in the front of the name, which is used to indicate the machine name. (Example:' A020124.190937.dat' ). To save the file either press the &amp;lt;QSAVE&amp;gt; button which saves the file in the current directory, indicated in the status line at the bottom of the window, or use the menu command &amp;lt;Save *.dat&amp;gt; under &amp;lt;File&amp;gt;. As long as the files has not been saved a ' * ' is attached to the file. The &amp;lt;Copy&amp;gt; copies the data in the left image to the second image on the right. &lt;br /&gt;
&lt;br /&gt;
The basic operations to display the data are done using the following buttons:&lt;br /&gt;
&lt;br /&gt;
 &amp;lt;DA&amp;gt;:  Display the image using different line by line subtraction modes &lt;br /&gt;
 &amp;lt;DX&amp;gt;:  Display the image using automatic plane substraction&lt;br /&gt;
 &amp;lt;DP&amp;gt;:  Display the image using plane substraction&lt;br /&gt;
 &amp;lt;LA&amp;gt;:  Display image in DA mode and perform automatic scaling&lt;br /&gt;
 &amp;lt;LP&amp;gt;:  Perform a low pass filter operation&lt;br /&gt;
 &amp;lt;HP&amp;gt;:  Perform a high pass filter operation&lt;br /&gt;
 &amp;lt;Pln&amp;gt;: Input 3 points (with the mouse) to determine the plane for plane background subtraction&lt;br /&gt;
 &amp;lt;Lin&amp;gt;: Calculate a linescan along a line between 2 points&lt;br /&gt;
 &amp;lt;LM&amp;gt;  Lateral manipulation&lt;br /&gt;
 &amp;lt;VM&amp;gt;  Vertical manipulation of I/V spectroscopy&lt;br /&gt;
 &amp;lt;TF&amp;gt;  Tip forming&lt;br /&gt;
&lt;br /&gt;
Use &amp;lt;Disp LinePlan Quad&amp;gt; under &amp;lt;Display&amp;gt; in the menu subtract to perform an automatic line/plane subtraction using also quadratic terms&lt;br /&gt;
Below the buttons you find the Palette window, which displays the current 8bit palette. Use the left mouse button to switch between different standard palettes. Using the right mouse button will open a popup menu with additional options to create a user defined palette or to load and save externally defined palettes.&lt;br /&gt;
&lt;br /&gt;
The small list box on the right is used for communication between different instances of the STMAFM program. If the instance of the program which is in data acquisition mode saves a file then this filename is send to all other instances of the program running in analysis mode.&lt;br /&gt;
&lt;br /&gt;
Below the buttons the screen is separated in two parts, divided by an horizontaly movable slider. On the left is always the image of the current data file displayed. All the operations like scanning and image processing are done in this part on the window. On the right usually a list of all loaded files is displayed. A small icon image and some info is shown for each file. The two modes to display these data are 'Report&amp;quot; and 'Icon' view. The modes can be selected under menu item 'Display'. When in Report view pressing on the 'Image' bar will switch the way how the info is displayed. The list view can be suppressed by selecting 'Image2' under menu item 'Display' and the second image is displayed instead.&lt;br /&gt;
&lt;br /&gt;
On the bottom of the window a status bar is located. It shows the current date and time, some status info about the scanning status, the mouse position on the image,the size of  the image, the current default directory, the available space of disk storage.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[file:clipstmafm.png|600px]]&lt;br /&gt;
&lt;br /&gt;
== Menu Structure ==&lt;br /&gt;
&lt;br /&gt;
'''File'''		                         &lt;br /&gt;
 Open  *.DAT            Open STMAFM DataFile&lt;br /&gt;
 Save  *.DAT            Save STMAFM DataFile&lt;br /&gt;
 QuickSave              Save STMAFM DataFile in active directory&lt;br /&gt;
			&lt;br /&gt;
 Export File		&lt;br /&gt;
 Save  *.BMP         	Save Image as BMP-File&lt;br /&gt;
 Save *.JPG		Save as JPEG File&lt;br /&gt;
 SaveEMF *.EMF           Save Image in EMF Format&lt;br /&gt;
 SaveAscii *.ASC   	Save Image-Data in ASCII Format&lt;br /&gt;
			&lt;br /&gt;
 Import File		&lt;br /&gt;
 Load *.BMP      	Load BMP File&lt;br /&gt;
 Load *.TIF		Load TIF File&lt;br /&gt;
			&lt;br /&gt;
 Print		&lt;br /&gt;
 Print Image             Print the image&lt;br /&gt;
 Print Listview          Print the Filelist in Listview&lt;br /&gt;
 Printer Setup           Select the printer&lt;br /&gt;
			&lt;br /&gt;
 Special		&lt;br /&gt;
 Compress Files		All Files are saved using Data compression with Zlib&lt;br /&gt;
 Save Listview-Files   	Save List of Files in the Listview window&lt;br /&gt;
 Autosave  *.bak       	Save all recorded images&lt;br /&gt;
 AutoSave All		Save all images&lt;br /&gt;
 DOS-CommandLine   	Open a DOS-Window&lt;br /&gt;
 HPData			Get Data from Agilent Datalogger&lt;br /&gt;
 Get_SRS_Lockin_Val	Get External Lockin Setup Parameters&lt;br /&gt;
 &lt;br /&gt;
 STMAFM-Analysis        Start another copy of the STMAFM-Program&lt;br /&gt;
 Exit                   Exit the STMAFM-Program&lt;br /&gt;
 About                  About &lt;br /&gt;
 ReOpen                 Opens the last file&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Edit    &lt;br /&gt;
 Copy Clipbd                Copy the image to the clipboard&lt;br /&gt;
 Copy Dataimage2            Copy left image to the right&lt;br /&gt;
 Copy Clipbd EMF            Copy the image to the clipboard in EMF Format with Info&lt;br /&gt;
 Copy New Window            Copy the image into new form&lt;br /&gt;
 Copy Overview              Copy the image into the overview form&lt;br /&gt;
 Copy Palette to Clipbd     Copy the palette to the Clipboard       &lt;br /&gt;
&lt;br /&gt;
Scan   &lt;br /&gt;
 Scan Start             		Start the Scan&lt;br /&gt;
 Scan Stop              		Stop the Scan&lt;br /&gt;
 Enable/Start RepeatTimer	Start the Repeat-Timer&lt;br /&gt;
 Preamplifier                 	Select the preamplifier&lt;br /&gt;
 Preamp_Femto_LowNoise  		Select for Femto Preamp in Low Noise Mode&lt;br /&gt;
 Preamp_Femto_HighSpeed 		Select for Femto Preamp in High Speed Mode&lt;br /&gt;
 Preamp_Femto_100G		Select for Femto Preamp with fixed gain 10^11&lt;br /&gt;
 Preamp_UserType			Select for User specific Preamp &lt;br /&gt;
&lt;br /&gt;
 Autofilesave			Save every image&lt;br /&gt;
 Autorepeat			Start a new image automatically&lt;br /&gt;
 Autodispreset         		Clear the image window when starting a new scan&lt;br /&gt;
&lt;br /&gt;
 Show Scanline Marker		Display a red line at the actual scan line position&lt;br /&gt;
 Display current Scan Profile	Display the current line as a line scan in a separate window&lt;br /&gt;
 &lt;br /&gt;
 Scan_Y_Direction		Select the Scandirection (Top-Bottom,Bottom-Top,etc)&lt;br /&gt;
 ScanCoarse			Check to set scanning by Coarse Piezos otherwise the main Piezo is used&lt;br /&gt;
&lt;br /&gt;
DSP       &lt;br /&gt;
 Lateral Manip.      		Lateral Manipulation&lt;br /&gt;
 Vertical Manip.            	Vertical Manipulation&lt;br /&gt;
 Tip Forming                	Tip Forming&lt;br /&gt;
&lt;br /&gt;
 SetXYOffset - Top           	Set the xy-offset for the new top site&lt;br /&gt;
 SetXYOffset - Center        	Set the xy-offset for the new center site&lt;br /&gt;
 SetXYOffset - Zoom        	Set the xy-offset for the new center site&lt;br /&gt;
 ResetXYOffset  			Set the xy-offset to (0,0)&lt;br /&gt;
 Copy Offset from Param    	Copy the xy-offset values from the scanparameterlist&lt;br /&gt;
 1: Offsetx,y:  0 0          	Select as new Offset&lt;br /&gt;
 2: Offsetx,y   0 0          	Select as new Offset&lt;br /&gt;
 3: Offsetx,y   0 0          	Select as new Offset&lt;br /&gt;
 4: Offsetx,y   0 0          	Select as new Offset&lt;br /&gt;
 Set_Plan_Dx_Dy			Set the parameters for the plan-offset. &lt;br /&gt;
 Set_DSP_Clock 			Change the Clock-Frequency of the DSP-FeedBack-Loop&lt;br /&gt;
 &lt;br /&gt;
Image   &lt;br /&gt;
 Undo Filter                 		Undo last image operation&lt;br /&gt;
 Filter&lt;br /&gt;
  LowPass                     	Low Pass Filter the image&lt;br /&gt;
  HighPass                    	High Pass Filter the image&lt;br /&gt;
  Laplace                     	Laplace Filter the image&lt;br /&gt;
  Median				Median Filter&lt;br /&gt;
  Edge(Horz)			Edge Filter in the horizontal direction&lt;br /&gt;
  Invert                      	Invert the image&lt;br /&gt;
  Imagedata * 10			The image data is multiplied by a factor of 10&lt;br /&gt;
  Imagedata / 10			The image data is divided by a factor of 10&lt;br /&gt;
&lt;br /&gt;
 Resize&lt;br /&gt;
  Zoom_Up_Rect              Zoom up a selected rectangle &lt;br /&gt;
  Resize   / 2                	Resize the image&lt;br /&gt;
  Resize   x 2                	Resize the image&lt;br /&gt;
  Interpolation  / 2          	Interpolate the image&lt;br /&gt;
  Interpolation  x 2          	Interpolate the image&lt;br /&gt;
       &lt;br /&gt;
 Rotate90deg&lt;br /&gt;
&lt;br /&gt;
 FFT&lt;br /&gt;
  FFT2D                       	Fast Fourier Transform&lt;br /&gt;
  FFT2D Invers                	Inverse FFT&lt;br /&gt;
  FFT2d Cutout               	Cutout a part of the FFT&lt;br /&gt;
  FFT Evaluate		Open FFT Evaluate window&lt;br /&gt;
&lt;br /&gt;
 Image Analysis&lt;br /&gt;
  Histogram                   	Show the histogram of the image&lt;br /&gt;
  Areacalculation             	Calculate the size of islands&lt;br /&gt;
  Islandsize                  	Calculate the size of islands&lt;br /&gt;
&lt;br /&gt;
Display&lt;br /&gt;
 Zoom&lt;br /&gt;
  100%&lt;br /&gt;
  200%&lt;br /&gt;
  300%&lt;br /&gt;
  400%&lt;br /&gt;
&lt;br /&gt;
 ListView&lt;br /&gt;
  Report			Show files as icons and info&lt;br /&gt;
  Icon			Show files as icons only&lt;br /&gt;
  Image2			Show Image2 and not the Listviewbox&lt;br /&gt;
  ListViewBox enabled      Enables the ListView Box	&lt;br /&gt;
  AutoclearList                	Clear the Listviewbox before new a new list is added&lt;br /&gt;
  Largeiconsize=64-256   	Icon size of the images in the listviewbox&lt;br /&gt;
  Load Icon Plan              	Load the icons using image plan subtraction&lt;br /&gt;
  Clear Listview		Clear the ListView&lt;br /&gt;
   	&lt;br /&gt;
 DispCommands &lt;br /&gt;
  DispAuto                    	Display image using linear line background subtraction &lt;br /&gt;
  DispPlanAuto                	Display image using auto plan background subtraction &lt;br /&gt;
  DispPlan                    	Display image using plan subtraction&lt;br /&gt;
  Last Disp Autoscale	Display with automatic scaling&lt;br /&gt;
  Plan Auto Subtract	Like Displanauto + subtract plane from image data&lt;br /&gt;
  Linescan                    	Linescan in the image&lt;br /&gt;
  Plan2dinput                 	Input 3 points to select the background subtraction plane&lt;br /&gt;
  Configuration&lt;br /&gt;
   DACunits                    	Select DAC units&lt;br /&gt;
   nm-Units [A]                	Select Angström units&lt;br /&gt;
  Display Image in Lines	Select to display image in line and not gray scale mode&lt;br /&gt;
  Disp LinePlan Quad	Select to perform lin.+quad. Backgroundsubtraction&lt;br /&gt;
  Disp Plan and Subtract	If selected Disp Plan subtracts the plane from the image data&lt;br /&gt;
  Disp Automode Offset/Slope   	DA Mode subtract offset and slope line by line&lt;br /&gt;
  Disp Automode Offset   	DA Mode subtract offset line by line&lt;br /&gt;
  Disp Automode None   	DA Mode subtract offset of first line&lt;br /&gt;
  Disp Automode Diff   	DA Mode differentiate image data line by line&lt;br /&gt;
	&lt;br /&gt;
Forms&lt;br /&gt;
 Parameter&lt;br /&gt;
 Lat.Manip                		Show the Latmanip window&lt;br /&gt;
 Vert.Manip               		Show the Vertmanip. window&lt;br /&gt;
 Time Spectrum			Show the Time Spectrum window&lt;br /&gt;
 AFM				Show the AFM PLL window&lt;br /&gt;
 Ramp-Controller			Start Ramp Controller&lt;br /&gt;
 New Channelform		Open another Channelform&lt;br /&gt;
 Linescan                		Show the linescan window&lt;br /&gt;
 Draw Grid			Show Grid window&lt;br /&gt;
 3dView				Show 3d View window	&lt;br /&gt;
 Memo				Show separate Memo window&lt;br /&gt;
 Overview                		Show the overview window&lt;br /&gt;
 Slider				Show the Slider window&lt;br /&gt;
 User Form			Show the User Form&lt;br /&gt;
 Reset Form Positions		Position all windows at (top,left) = (0,0)&lt;br /&gt;
 Show/Hide Old Param 		Show/Hide the old Parameter window&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Debug   &lt;br /&gt;
 Reset Scanstatus            	Enable all buttons again&lt;br /&gt;
 Remote				Open Remote window&lt;br /&gt;
 Client Server Control		Open Client Server Control&lt;br /&gt;
 FIFO_COM USB2.0                Shows whether communication is by USB2.0 Hardware&lt;br /&gt;
 Build Testimage                Build a new image without scanning&lt;br /&gt;
 STM Simulation			Run the STM Programm in Simulation Mode (with DSP) &lt;br /&gt;
 PLL Off                        Switch PLL off&lt;br /&gt;
 Debug Messages On   		Show Debug messages&lt;br /&gt;
 Block Data Transfer		Transfer Data after Acquitstion has been done&lt;br /&gt;
 ADDA DSP Connect		Manually start/stop communication between DSP and ADDA&lt;br /&gt;
 Form Memory Watch		Shows some status data&lt;br /&gt;
       &lt;br /&gt;
&lt;br /&gt;
Tools&lt;br /&gt;
 Tip-Etching			Open to etch STM tips&lt;br /&gt;
 Initialization			Open Initialization window&lt;br /&gt;
 Data Recorder			Open Datarecorder window&lt;br /&gt;
 Flash Utility			Utility to burn Flash on DSP Board with new DSP software&lt;br /&gt;
	&lt;br /&gt;
Help&lt;br /&gt;
 Show STMAFM-Manual		Show STMAFM Manual (PDF)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Main Buttons ==&lt;br /&gt;
&amp;lt;Start&amp;gt;     or 	&amp;lt;F1&amp;gt;:  	Start the scan&lt;br /&gt;
           &lt;br /&gt;
&amp;lt;Stop&amp;gt; 	    or 	&amp;lt;F2&amp;gt;:  	Stop the scan&lt;br /&gt;
&lt;br /&gt;
&amp;lt;Qsave&amp;gt;   or 	&amp;lt;F3&amp;gt;: 	Automatically saves an image in the actual directory&lt;br /&gt;
&lt;br /&gt;
&amp;lt;Copy&amp;gt;     or 	&amp;lt;F4&amp;gt;: 	Copy Image1 to Image2&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LM&amp;gt;        or 	&amp;lt;F5&amp;gt;:	Perform a lateral manipulation&lt;br /&gt;
&lt;br /&gt;
&amp;lt;VM&amp;gt; 	    or 	&amp;lt;F6&amp;gt;:	Perform a vertical manipulation or spectroscopy&lt;br /&gt;
&lt;br /&gt;
&amp;lt;TF&amp;gt; 	    or 	&amp;lt;F8&amp;gt;:	Perform tip forming&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DA&amp;gt; 	    or 	&amp;lt;F9&amp;gt;: 	Display the image with automatic line by line background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DX&amp;gt; 	    or 	&amp;lt;F10&amp;gt;:  Display the image with automatic plane background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DP&amp;gt; 	    or 	&amp;lt;F11&amp;gt;: 	Display the image with planar background subtraction with predefined parameters&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LA&amp;gt;        or  &amp;lt;F12&amp;gt;: Display the image with automatic greyscale scaling&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LP&amp;gt; 	or    &amp;lt;Shift F9&amp;gt;:       Low pass filter&lt;br /&gt;
 &lt;br /&gt;
&amp;lt;HP&amp;gt; 	or   &amp;lt;Shift F10&amp;gt;:	High pass filter&lt;br /&gt;
&lt;br /&gt;
&amp;lt;PLN&amp;gt; 	or   &amp;lt;Shift F11&amp;gt;:	Input 3 points for the plane used in plane background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LIN&amp;gt; 	or   &amp;lt;Shift F12&amp;gt;:	Display a linear scan between two points on the image&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==  ==&lt;br /&gt;
[[category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=STMAFM_Main</id>
		<title>STMAFM Main</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=STMAFM_Main"/>
				<updated>2014-09-15T10:39:39Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Main Form ==&lt;br /&gt;
The STMAFM form contains the main control elements of the software. Below the menu bar several control the data acquisition and analysis of the STM data.&lt;br /&gt;
&lt;br /&gt;
To take a new image press the &amp;lt;START&amp;gt; button. To stop press the &amp;lt;STOP&amp;gt; button. When a new scan is started a default filename is assigned to the image. It consists of the date and time, when the scan was started. Its extension will be '.dat'. A single letter is put in the front of the name, which is used to indicate the machine name. (Example:' A020124.190937.dat' ). To save the file either press the &amp;lt;QSAVE&amp;gt; button which saves the file in the current directory, indicated in the status line at the bottom of the window, or use the menu command &amp;lt;Save *.dat&amp;gt; under &amp;lt;File&amp;gt;. As long as the files has not been saved a ' * ' is attached to the file. The &amp;lt;Copy&amp;gt; copies the data in the left image to the second image on the right. &lt;br /&gt;
&lt;br /&gt;
The basic operations to display the data are done using the following buttons:&lt;br /&gt;
&lt;br /&gt;
 &amp;lt;DA&amp;gt;:  Display the image using different line by line subtraction modes &lt;br /&gt;
 &amp;lt;DX&amp;gt;:  Display the image using automatic plane substraction&lt;br /&gt;
 &amp;lt;DP&amp;gt;:  Display the image using plane substraction&lt;br /&gt;
 &amp;lt;LA&amp;gt;:  Display image in DA mode and perform automatic scaling&lt;br /&gt;
 &amp;lt;LP&amp;gt;:  Perform a low pass filter operation&lt;br /&gt;
 &amp;lt;HP&amp;gt;:  Perform a high pass filter operation&lt;br /&gt;
 &amp;lt;Pln&amp;gt;: Input 3 points (with the mouse) to determine the plane for plane background subtraction&lt;br /&gt;
 &amp;lt;Lin&amp;gt;: Calculate a linescan along a line between 2 points&lt;br /&gt;
 &amp;lt;LM&amp;gt;  Lateral manipulation&lt;br /&gt;
 &amp;lt;VM&amp;gt;  Vertical manipulation of I/V spectroscopy&lt;br /&gt;
 &amp;lt;TF&amp;gt;  Tip forming&lt;br /&gt;
&lt;br /&gt;
Use &amp;lt;Disp LinePlan Quad&amp;gt; under &amp;lt;Display&amp;gt; in the menu subtract to perform an automatic line/plane subtraction using also quadratic terms&lt;br /&gt;
Below the buttons you find the Palette window, which displays the current 8bit palette. Use the left mouse button to switch between different standard palettes. Using the right mouse button will open a popup menu with additional options to create a user defined palette or to load and save externally defined palettes.&lt;br /&gt;
&lt;br /&gt;
The small list box on the right is used for communication between different instances of the STMAFM program. If the instance of the program which is in data acquisition mode saves a file then this filename is send to all other instances of the program running in analysis mode.&lt;br /&gt;
&lt;br /&gt;
Below the buttons the screen is separated in two parts, divided by an horizontaly movable slider. On the left is always the image of the current data file displayed. All the operations like scanning and image processing are done in this part on the window. On the right usually a list of all loaded files is displayed. A small icon image and some info is shown for each file. The two modes to display these data are 'Report&amp;quot; and 'Icon' view. The modes can be selected under menu item 'Display'. When in Report view pressing on the 'Image' bar will switch the way how the info is displayed. The list view can be suppressed by selecting 'Image2' under menu item 'Display' and the second image is displayed instead.&lt;br /&gt;
&lt;br /&gt;
On the bottom of the window a status bar is located. It shows the current date and time, some status info about the scanning status, the mouse position on the image,the size of  the image, the current default directory, the available space of disk storage.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[file:clipstmafm.png|600px]]&lt;br /&gt;
&lt;br /&gt;
== Menu Structure ==&lt;br /&gt;
&lt;br /&gt;
'''File'''		                         &lt;br /&gt;
 Open  *.DAT            Open STMAFM DataFile&lt;br /&gt;
 Save  *.DAT            Save STMAFM DataFile&lt;br /&gt;
 QuickSave              Save STMAFM DataFile in active directory&lt;br /&gt;
			&lt;br /&gt;
 Export File		&lt;br /&gt;
 Save  *.BMP         	Save Image as BMP-File&lt;br /&gt;
 Save *.JPG		Save as JPEG File&lt;br /&gt;
 SaveEMF *.EMF           Save Image in EMF Format&lt;br /&gt;
 SaveAscii *.ASC   	Save Image-Data in ASCII Format&lt;br /&gt;
			&lt;br /&gt;
 Import File		&lt;br /&gt;
 Load *.BMP      	Load BMP File&lt;br /&gt;
 Load *.TIF		Load TIF File&lt;br /&gt;
			&lt;br /&gt;
 Print		&lt;br /&gt;
 Print Image             Print the image&lt;br /&gt;
 Print Listview          Print the Filelist in Listview&lt;br /&gt;
 Printer Setup           Select the printer&lt;br /&gt;
			&lt;br /&gt;
 Special		&lt;br /&gt;
 Compress Files		All Files are saved using Data compression with Zlib&lt;br /&gt;
 Save Listview-Files   	Save List of Files in the Listview window&lt;br /&gt;
 Autosave  *.bak       	Save all recorded images&lt;br /&gt;
 AutoSave All		Save all images&lt;br /&gt;
 DOS-CommandLine   	Open a DOS-Window&lt;br /&gt;
 HPData			Get Data from Agilent Datalogger&lt;br /&gt;
 Get_SRS_Lockin_Val	Get External Lockin Setup Parameters&lt;br /&gt;
 &lt;br /&gt;
 STMAFM-Analysis        Start another copy of the STMAFM-Program&lt;br /&gt;
 Exit                   Exit the STMAFM-Program&lt;br /&gt;
 About                  About &lt;br /&gt;
 ReOpen                 Opens the last file&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Edit    &lt;br /&gt;
 Copy Clipbd                Copy the image to the clipboard&lt;br /&gt;
 Copy Dataimage2            Copy left image to the right&lt;br /&gt;
 Copy Clipbd EMF            Copy the image to the clipboard in EMF Format with Info&lt;br /&gt;
 Copy New Window            Copy the image into new form&lt;br /&gt;
 Copy Overview              Copy the image into the overview form&lt;br /&gt;
 Copy Palette to Clipbd     Copy the palette to the Clipboard       &lt;br /&gt;
&lt;br /&gt;
Scan   &lt;br /&gt;
 Scan Start               		Start the Scan&lt;br /&gt;
 Scan Stop                		Stop the Scan&lt;br /&gt;
 Enable/Start RepeatTimer 	Start the Repeat-Timer&lt;br /&gt;
 Preamplifier                    	Select the preamplifier&lt;br /&gt;
 Preamp_Femto_LowNoise  		Select for Femto Preamp in Low Noise Mode&lt;br /&gt;
 Preamp_Femto_HighSpeed 		Select for Femto Preamp in High Speed Mode&lt;br /&gt;
 Preamp_Femto_100G		Select for Femto Preamp with fixed gain 10^11&lt;br /&gt;
 Preamp_UserType			Select for User specific Preamp &lt;br /&gt;
&lt;br /&gt;
 Autofilesave		Save every image&lt;br /&gt;
 Autorepeat		Start a new image automatically&lt;br /&gt;
 Autodispreset         		Clear the image window when starting a new scan&lt;br /&gt;
&lt;br /&gt;
 Show Scanline Marker		Display a red line at the actual scan line position&lt;br /&gt;
 Display current Scan Profile	Display the current line as a line scan in a separate window&lt;br /&gt;
 &lt;br /&gt;
 Scan_Y_Direction		Select the Scandirection (Top-Bottom,Bottom-Top,etc)&lt;br /&gt;
 ScanCoarse			Check to set scanning by Coarse Piezos otherwise the main Piezo is used&lt;br /&gt;
&lt;br /&gt;
DSP       &lt;br /&gt;
 Lateral Manip.      		Lateral Manipulation&lt;br /&gt;
 Vertical Manip.            	 	Vertical Manipulation&lt;br /&gt;
 Tip Forming                 		Tip Forming&lt;br /&gt;
&lt;br /&gt;
 SetXYOffset - Top           	Set the xy-offset for the new top site&lt;br /&gt;
 SetXYOffset - Center        	Set the xy-offset for the new center site&lt;br /&gt;
 SetXYOffset - Zoom        	Set the xy-offset for the new center site&lt;br /&gt;
 ResetXYOffset  			Set the xy-offset to (0,0)&lt;br /&gt;
 Copy Offset from Param    	Copy the xy-offset values from the scanparameterlist&lt;br /&gt;
 1: Offsetx,y:  0 0          		Select as new Offset&lt;br /&gt;
 2: Offsetx,y   0 0          		Select as new Offset&lt;br /&gt;
 3: Offsetx,y   0 0          		Select as new Offset&lt;br /&gt;
 4: Offsetx,y   0 0          		Select as new Offset&lt;br /&gt;
 Set_Plan_Dx_Dy		Set the parameters for the plan-offset. &lt;br /&gt;
 Set_DSP_Clock 		Change the Clock-Frequency of the DSP-FeedBack-Loop&lt;br /&gt;
 &lt;br /&gt;
Image   &lt;br /&gt;
 Undo Filter                 		Undo last image operation&lt;br /&gt;
 Filter&lt;br /&gt;
  LowPass                     	Low Pass Filter the image&lt;br /&gt;
  HighPass                    	High Pass Filter the image&lt;br /&gt;
  Laplace                     	Laplace Filter the image&lt;br /&gt;
  Median			Median Filter&lt;br /&gt;
  Edge(Horz)		Edge Filter in the horizontal direction&lt;br /&gt;
  Invert                      	Invert the image&lt;br /&gt;
  Imagedata * 10		The image data is multiplied by a factor of 10&lt;br /&gt;
  Imagedata / 10		The image data is divided by a factor of 10&lt;br /&gt;
&lt;br /&gt;
 Resize&lt;br /&gt;
  Zoom_Up_Rect              Zoom up a selected rectangle &lt;br /&gt;
  Resize   / 2                	Resize the image&lt;br /&gt;
  Resize   x 2                	Resize the image&lt;br /&gt;
  Interpolation  / 2          	Interpolate the image&lt;br /&gt;
  Interpolation  x 2          	Interpolate the image&lt;br /&gt;
       &lt;br /&gt;
 Rotate90deg&lt;br /&gt;
&lt;br /&gt;
 FFT&lt;br /&gt;
  FFT2D                       	Fast Fourier Transform&lt;br /&gt;
  FFT2D Invers                	Inverse FFT&lt;br /&gt;
  FFT2d Cutout               	Cutout a part of the FFT&lt;br /&gt;
  FFT Evaluate		Open FFT Evaluate window&lt;br /&gt;
&lt;br /&gt;
 Image Analysis&lt;br /&gt;
  Histogram                   	Show the histogram of the image&lt;br /&gt;
  Areacalculation             	Calculate the size of islands&lt;br /&gt;
  Islandsize                  	Calculate the size of islands&lt;br /&gt;
&lt;br /&gt;
Display&lt;br /&gt;
 Zoom&lt;br /&gt;
  100%&lt;br /&gt;
  200%&lt;br /&gt;
  300%&lt;br /&gt;
  400%&lt;br /&gt;
&lt;br /&gt;
 ListView&lt;br /&gt;
  Report			Show files as icons and info&lt;br /&gt;
  Icon			Show files as icons only&lt;br /&gt;
  Image2			Show Image2 and not the Listviewbox&lt;br /&gt;
  ListViewBox enabled      Enables the ListView Box	&lt;br /&gt;
  AutoclearList                	Clear the Listviewbox before new a new list is added&lt;br /&gt;
  Largeiconsize=64-256   	Icon size of the images in the listviewbox&lt;br /&gt;
  Load Icon Plan              	Load the icons using image plan subtraction&lt;br /&gt;
  Clear Listview		Clear the ListView&lt;br /&gt;
   	&lt;br /&gt;
 DispCommands &lt;br /&gt;
  DispAuto                    	Display image using linear line background subtraction &lt;br /&gt;
  DispPlanAuto                	Display image using auto plan background subtraction &lt;br /&gt;
  DispPlan                    	Display image using plan subtraction&lt;br /&gt;
  Last Disp Autoscale	Display with automatic scaling&lt;br /&gt;
  Plan Auto Subtract	Like Displanauto + subtract plane from image data&lt;br /&gt;
  Linescan                    	Linescan in the image&lt;br /&gt;
  Plan2dinput                 	Input 3 points to select the background subtraction plane&lt;br /&gt;
  Configuration&lt;br /&gt;
   DACunits                    	Select DAC units&lt;br /&gt;
   nm-Units [A]                	Select Angström units&lt;br /&gt;
  Display Image in Lines	Select to display image in line and not gray scale mode&lt;br /&gt;
  Disp LinePlan Quad	Select to perform lin.+quad. Backgroundsubtraction&lt;br /&gt;
  Disp Plan and Subtract	If selected Disp Plan subtracts the plane from the image data&lt;br /&gt;
  Disp Automode Offset/Slope   	DA Mode subtract offset and slope line by line&lt;br /&gt;
  Disp Automode Offset   	DA Mode subtract offset line by line&lt;br /&gt;
  Disp Automode None   	DA Mode subtract offset of first line&lt;br /&gt;
  Disp Automode Diff   	DA Mode differentiate image data line by line&lt;br /&gt;
	&lt;br /&gt;
Forms&lt;br /&gt;
 Parameter&lt;br /&gt;
 Lat.Manip                		Show the Latmanip window&lt;br /&gt;
 Vert.Manip               		Show the Vertmanip. window&lt;br /&gt;
 Time Spectrum			Show the Time Spectrum window&lt;br /&gt;
 AFM				Show the AFM PLL window&lt;br /&gt;
 Ramp-Controller			Start Ramp Controller&lt;br /&gt;
 New Channelform		Open another Channelform&lt;br /&gt;
 Linescan                		Show the linescan window&lt;br /&gt;
 Draw Grid			Show Grid window&lt;br /&gt;
 3dView				Show 3d View window	&lt;br /&gt;
 Memo				Show separate Memo window&lt;br /&gt;
 Overview                		Show the overview window&lt;br /&gt;
 Slider				Show the Slider window&lt;br /&gt;
 User Form			Show the User Form&lt;br /&gt;
 Reset Form Positions		Position all windows at (top,left) = (0,0)&lt;br /&gt;
 Show/Hide Old Param 		Show/Hide the old Parameter window&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Debug   &lt;br /&gt;
 Reset Scanstatus            	Enable all buttons again&lt;br /&gt;
 Remote				Open Remote window&lt;br /&gt;
 Client Server Control		Open Client Server Control&lt;br /&gt;
 FIFO_COM USB2.0                Shows whether communication is by USB2.0 Hardware&lt;br /&gt;
 Build Testimage                Build a new image without scanning&lt;br /&gt;
 STM Simulation			Run the STM Programm in Simulation Mode (with DSP) &lt;br /&gt;
 PLL Off                        Switch PLL off&lt;br /&gt;
 Debug Messages On   		Show Debug messages&lt;br /&gt;
 Block Data Transfer		Transfer Data after Acquitstion has been done&lt;br /&gt;
 ADDA DSP Connect		Manually start/stop communication between DSP and ADDA&lt;br /&gt;
 Form Memory Watch		Shows some status data&lt;br /&gt;
       &lt;br /&gt;
&lt;br /&gt;
Tools&lt;br /&gt;
 Tip-Etching			Open to etch STM tips&lt;br /&gt;
 Initialization			Open Initialization window&lt;br /&gt;
 Data Recorder			Open Datarecorder window&lt;br /&gt;
 Flash Utility			Utility to burn Flash on DSP Board with new DSP software&lt;br /&gt;
	&lt;br /&gt;
Help&lt;br /&gt;
 Show STMAFM-Manual		Show STMAFM Manual (PDF)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Main Buttons ==&lt;br /&gt;
&amp;lt;Start&amp;gt;     or 	&amp;lt;F1&amp;gt;:  	Start the scan&lt;br /&gt;
           &lt;br /&gt;
&amp;lt;Stop&amp;gt; 	    or 	&amp;lt;F2&amp;gt;:  	Stop the scan&lt;br /&gt;
&lt;br /&gt;
&amp;lt;Qsave&amp;gt;   or 	&amp;lt;F3&amp;gt;: 	Automatically saves an image in the actual directory&lt;br /&gt;
&lt;br /&gt;
&amp;lt;Copy&amp;gt;     or 	&amp;lt;F4&amp;gt;: 	Copy Image1 to Image2&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LM&amp;gt;        or 	&amp;lt;F5&amp;gt;:	Perform a lateral manipulation&lt;br /&gt;
&lt;br /&gt;
&amp;lt;VM&amp;gt; 	    or 	&amp;lt;F6&amp;gt;:	Perform a vertical manipulation or spectroscopy&lt;br /&gt;
&lt;br /&gt;
&amp;lt;TF&amp;gt; 	    or 	&amp;lt;F8&amp;gt;:	Perform tip forming&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DA&amp;gt; 	    or 	&amp;lt;F9&amp;gt;: 	Display the image with automatic line by line background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DX&amp;gt; 	    or 	&amp;lt;F10&amp;gt;:  Display the image with automatic plane background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;DP&amp;gt; 	    or 	&amp;lt;F11&amp;gt;: 	Display the image with planar background subtraction with predefined parameters&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LA&amp;gt;        or  &amp;lt;F12&amp;gt;: Display the image with automatic greyscale scaling&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LP&amp;gt; 	or    &amp;lt;Shift F9&amp;gt;:       Low pass filter&lt;br /&gt;
 &lt;br /&gt;
&amp;lt;HP&amp;gt; 	or   &amp;lt;Shift F10&amp;gt;:	High pass filter&lt;br /&gt;
&lt;br /&gt;
&amp;lt;PLN&amp;gt; 	or   &amp;lt;Shift F11&amp;gt;:	Input 3 points for the plane used in plane background subtraction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;LIN&amp;gt; 	or   &amp;lt;Shift F12&amp;gt;:	Display a linear scan between two points on the image&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==  ==&lt;br /&gt;
[[category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Hardware_2.0</id>
		<title>Hardware 2.0</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Hardware_2.0"/>
				<updated>2014-09-15T09:46:43Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The new electronics is based on the new TMS320C6657 DSP from TI. Communication between the PC and the electronics is based on a Gigabit Ethernet connection.&lt;br /&gt;
&lt;br /&gt;
It is expected that the PC is running the 64bit Version of Windows 7.&lt;br /&gt;
&lt;br /&gt;
In the standard configuation the software running on the DSP board is loaded from the PC after startup of the electronics. It is therefore necessary to install a TFTP Server on the PC.&lt;br /&gt;
&lt;br /&gt;
In more detail:&lt;br /&gt;
&lt;br /&gt;
Install an Ethernet adapter in the host PC, which is dedicated to communication with the Electronics. &lt;br /&gt;
&lt;br /&gt;
The address of this adapter has to be 192.168.1.2. Subnet Mask: 255.255.255.0 Gateway 192.168.1.1&lt;br /&gt;
&lt;br /&gt;
A suitable TFTP Server is TFTPD64. A suitable *.ini file will be supplied as below:&lt;br /&gt;
&lt;br /&gt;
The name of the downloaded file is C6657le.bin&lt;br /&gt;
&lt;br /&gt;
Start the TFTP server first, then start the electronics. There should be an Gigabit ethernet switch between the electronics and the PC.&lt;br /&gt;
&lt;br /&gt;
After loading the *.bin file a message is displayed in the TFTP server window. The download and startup can take up to 1min.&lt;br /&gt;
&lt;br /&gt;
After booting successfully the new electronics appears with address 192.168.1.102. It should respond to the &amp;quot;ping&amp;quot; command.&lt;br /&gt;
Now you may start the PSTMAFM program on the PC. Please select HW_platform 5: C6657 in the Initialization form, save and restart the program.&lt;br /&gt;
&lt;br /&gt;
To change the IP address from the default value of 192.168.1.102:&lt;br /&gt;
&lt;br /&gt;
# In Initialization change the IP address and press Save to Flash button.&lt;br /&gt;
# Afterwards quit the STM Program.&lt;br /&gt;
# Change the IP Adress of the network card.&lt;br /&gt;
# If you changed the subnet, please change the corresponding parameters in the TFTP Server.&lt;br /&gt;
# Reboot the DSP (turn off, wait 5s, turn on).&lt;br /&gt;
# Upon software restart the DSP will appear under the new address.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation</id>
		<title>Hardware Driver Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation"/>
				<updated>2014-09-15T09:32:01Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The Createc electronics is based on the SBC6711 DSP board manufactured by Innovative Integration.&lt;br /&gt;
&lt;br /&gt;
All communication between the SBC6711 and the PC is made via USB1.1.&lt;br /&gt;
&lt;br /&gt;
An FPGA addon board called  XEM3001 manufactured by OPAL Kelly provides a separate fast USB2.0 connection between PC and SBC6711.&lt;br /&gt;
&lt;br /&gt;
This board is optional under Windows XP but necessary to allow operation under Windows 7 (64bit), because no device driver for the SBC6711 is available under Windows 7.&lt;br /&gt;
&lt;br /&gt;
There are two basic operating modes of the SBC6711 board. In the first (default for WinXP) case the DSP program is downloaded via the USB 1.1 interface onto the SBC6711 during the initial boot process after power-on or reset every time the STMAFM software is started. In the second case the DSP program resides inside the Flash memory on the SBC6711 board. It is started directly from the board, i.e. no download is necessary. This second mode allows operating the SBC6711 without a device driver - a requirement for Windows 7 operation and an option for WinXP.&lt;br /&gt;
&lt;br /&gt;
Because of these two modes as well as of historic reasons different boot configurations exist and the correct drivers and dlls have to be supplied. The different operating modes can be set in the stmafm.ini. Please goto Tools --&amp;gt; Initialization and select the parameter HW_platform (0: No Board).&lt;br /&gt;
&lt;br /&gt;
HW-platform: 1. Windows XP, SBC6711 (HW-Platform: 1)&lt;br /&gt;
The SBC6711 driver has to be installed and the SBC6711.dll has to be in the program directory. The DSP program in the form of an SBC6711*.out file resides also in the program directory. It is automatically extracted from the pstmafm.exe file when the program is started. The DSP boot file is supplied via USB1.1. The STM program will use USB1.1.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 2. Windows XP, SBC6711, XEM3001 (firmware 2.x)&lt;br /&gt;
Additionally the files okfrontpanel.dll and stmafm2fifo.bit have to be located in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 3. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additionally to 1. the files okfrontpanel32bitver3.dll and createc.bit have to be in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0. The newer firmware in the XEM3001 is required for Windows 7 compatibility only.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 4. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additional to 3. a SBC6711*.bin file has to be flashed into onboard FlashROM using the programs Flash utility from the Tools menu. The DSP will boot from flash. The STM program will use USB2.0. The driver for the XEM3001 has to be installed, the SBC6711 driver is not necessary as the USB1.1 is not used any more.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 4. Windows 7 (64bit), SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Same as above, but the XEM3001 driver located in the program directory is named okfrontpanel64bit.dll. The DSP will boot from flash. The STM program will use USB2.0. The driver for the XEM3001 has to be installed, there is no SBC6711 driver available. &lt;br /&gt;
&lt;br /&gt;
Remarks:&lt;br /&gt;
For new installations XEM3001 firmware 3.x is recommended as it allows booting from flash.&lt;br /&gt;
&lt;br /&gt;
XEM3001 firmware files&lt;br /&gt;
&lt;br /&gt;
Frontpanel 32-bit software for firmware 2.x&lt;br /&gt;
Frontpanel 32-bit software for firmware 3.x&lt;br /&gt;
Frontpanel 64-bit software for firmware 3.x&lt;br /&gt;
&lt;br /&gt;
Okfrontpanel.dll&lt;br /&gt;
okfrontpanel32bitV3.dll&lt;br /&gt;
okfrontpanel64bit.dll&lt;br /&gt;
&lt;br /&gt;
Createc.bit&lt;br /&gt;
stmafm2fifo.bit &lt;br /&gt;
&lt;br /&gt;
To switch from HW-platform 2 or 3 (booting from USB1.1) to 4 (booting from flash), please follow these instructions.&lt;br /&gt;
&lt;br /&gt;
[[Category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation</id>
		<title>Hardware Driver Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation"/>
				<updated>2014-09-15T09:18:31Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The Createc Electronics is based on the SBC6711 DSP board manufactured by Innovative Integration.&lt;br /&gt;
&lt;br /&gt;
All communication between the SBC6711 and the PC is made via USB1.1.&lt;br /&gt;
&lt;br /&gt;
An FPGA addon board called  XEM3001 manufactured by OPAL Kelly provides a separate fast USB2.0 connection between PC and SBC6711.&lt;br /&gt;
&lt;br /&gt;
This board is optional under Windows XP but necessary to allow operation under Windows 7 (64bit), because no device driver for the SBC6711 is available under Windows 7.&lt;br /&gt;
&lt;br /&gt;
There are two basic operating modes of the SBC6711 board. In the first (default for WinXP) case the DSP program is downloaded via the USB 1.1 interface onto the SBC6711 during the initial boot process after power-on or reset every time the STMAFM software is started. In the second case the DSP program resides inside the Flash memory on the SBC6711 board. It is started directly from the board, i.e. no download is necessary. This second mode allows operating the SBC6711 without a device driver - a requirement for Windows 7 operation and an option for WinXP.&lt;br /&gt;
&lt;br /&gt;
Because of these two modes as well as of historic reasons different boot configurations exist and the correct drivers and dlls have to be supplied. The different operating modes can be set in the stmafm.ini. Please goto Tools --&amp;gt; Initialization and select the parameter HW_platform (0: No Board).&lt;br /&gt;
&lt;br /&gt;
HW-platform: 1. Windows XP, SBC6711 (HW-Platform: 1)&lt;br /&gt;
The SBC6711 driver has to be installed and the SBC6711.dll has to be in the program directory. The DSP program in the form of an SBC6711*.out file resides also in the program directory. It is automatically extracted from the pstmafm.exe file when the program is started. The DSP boot file is supplied via USB1.1. The STM program will use USB1.1.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 2. Windows XP, SBC6711, XEM3001 (firmware 2.x)&lt;br /&gt;
Additionally the files okfrontpanel.dll and stmafm2fifo.bit have to be located in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 3. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additionally to 1. the files okfrontpanel32bitver3.dll and createc.bit have to be in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0. The newer firmware in the XEM3001 is required for Windows 7 compatibility only.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 4. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additional to 3. a SBC6711*.bin file has to be flashed into onboard FlashROM using the programs Flash utility from the Tools menu. The DSP will boot from flash. The STM program will use USB2.0. The driver for the XEM3001 has to be installed, the SBC6711 driver is not necessary as the USB1.1 is not used any more.&lt;br /&gt;
&lt;br /&gt;
HW-platform: 4. Windows 7 (64bit), SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Same as above, but the XEM3001 driver located in the program directory is named okfrontpanel64bit.dll. The DSP will boot from flash. The STM program will use USB2.0. The driver for the XEM3001 has to be installed, there is no SBC6711 driver available. &lt;br /&gt;
&lt;br /&gt;
Remarks:&lt;br /&gt;
For new installations XEM3001 Firmware 3.x is recommended as it allows booting from Flash.&lt;br /&gt;
&lt;br /&gt;
The files:&lt;br /&gt;
&lt;br /&gt;
XEM3001 firmware files : &lt;br /&gt;
&lt;br /&gt;
Old Firmware:  Vers. 2.5    FrontPanel1-Legacy.FrmPkg&lt;br /&gt;
&lt;br /&gt;
Latest Firmware;  Vers. 3.1  FrontPanel3p1-Update.FrmPkg&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Frontpanel Software Installation:&lt;br /&gt;
&lt;br /&gt;
2.5 Firmware: FrontPanel-v1.3.1-Setup.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware:  FrontPanelUSB-Win-Win4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware 64bit: FrontPanelUSB-Win-x4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
Bit files:&lt;br /&gt;
&lt;br /&gt;
3.1 Createc.bit&lt;br /&gt;
&lt;br /&gt;
2.5 stmafm2fifo.bit &lt;br /&gt;
&lt;br /&gt;
DLL's:&lt;br /&gt;
&lt;br /&gt;
Version 2  Okfrontpanel.dll&lt;br /&gt;
&lt;br /&gt;
Version3 32bit okfrontpanel32bitV3.dll&lt;br /&gt;
&lt;br /&gt;
Version3 64bit okfrontpanel64bit.dll&lt;br /&gt;
&lt;br /&gt;
In the initialization file stmafm.ini the flags:&lt;br /&gt;
&lt;br /&gt;
Enable_USB, FlashBoot, OpalKellyVer3 have to properly set to select a particular boot configuration.&lt;br /&gt;
&lt;br /&gt;
[[Category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation</id>
		<title>Hardware Driver Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation"/>
				<updated>2014-09-15T09:14:37Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The Createc Electronics is based on the SBC6711 DSP board manufactured by Innovative Integration.&lt;br /&gt;
&lt;br /&gt;
All communication between the SBC6711 and the PC is made via USB1.1.&lt;br /&gt;
&lt;br /&gt;
An FPGA addon board called  XEM3001 manufactured by OPAL Kelly provides a separate fast USB2.0 connection between PC and SBC6711.&lt;br /&gt;
&lt;br /&gt;
This board is optional under Windows XP but necessary to allow operation under Windows 7 (64bit), because no device driver for the SBC6711 is available under Windows 7.&lt;br /&gt;
&lt;br /&gt;
There are two basic operating modes of the SBC6711 board. In the first (default for WinXP) case the DSP program is downloaded via the USB 1.1 interface onto the SBC6711 during the initial boot process after power-on or reset every time the STMAFM software is started. In the second case the DSP program resides inside the Flash memory on the SBC6711 board. It is started directly from the board, i.e. no download is necessary. This second mode allows operating the SBC6711 without a device driver - a requirement for Windows 7 operation and an option for WinXP.&lt;br /&gt;
&lt;br /&gt;
Because of these two modes as well as of historic reasons different boot configurations exist and the correct drivers and dlls have to be supplied. The different operating modes can be set in the stmafm.ini. Please goto Tools --&amp;gt; Initialization and select the parameter HW_platform (0: No Board).&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 1. Windows XP, SBC6711 (HW-Platform: 1)&lt;br /&gt;
The SBC6711 driver has to be installed and the SBC6711.dll has to be in the program directory. The DSP program in the form of an SBC6711*.out file resides also in the program directory. It is automatically extracted from the pstmafm.exe file when the program is started. The DSP boot file is supplied via USB1.1. The STM program will use USB1.1.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 2. Windows XP, SBC6711, XEM3001 (firmware 2.x)&lt;br /&gt;
Additionally the files okfrontpanel.dll and stmafm2fifo.bit have to be located in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 3. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additionally to 1. the files okfrontpanel32bitver3.dll and createc.bit have to be in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0. The newer firmware in the XEM3001 is required for Windows 7 compatibility only.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 4. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additional to 3. a SBC6711*.bin file has to be flashed into onboard FlashROM using the programs Flash utility from the Tools menu. The DSP will boot from flash. The STM program will use USB2.0. The driver for the XEM3001 has to be installed, the SBC6711 driver is not necessary as the USB1.1 is not used any more.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 4. Windows 7 (64bit), SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Same as above, but the XEM3001 driver located in the program directory is named okfrontpanel64bit.dll. The DSP will boot from flash. The STM program will use USB2.0. The driver for the XEM3001 has to be installed, there is no SBC6711 driver available. &lt;br /&gt;
&lt;br /&gt;
Remarks:&lt;br /&gt;
For new installations XEM3001 Firmware 3.x is recommended as it allows booting from Flash.&lt;br /&gt;
&lt;br /&gt;
The files:&lt;br /&gt;
&lt;br /&gt;
XEM3001 firmware files : &lt;br /&gt;
&lt;br /&gt;
Old Firmware:  Vers. 2.5    FrontPanel1-Legacy.FrmPkg&lt;br /&gt;
&lt;br /&gt;
Latest Firmware;  Vers. 3.1  FrontPanel3p1-Update.FrmPkg&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Frontpanel Software Installation:&lt;br /&gt;
&lt;br /&gt;
2.5 Firmware: FrontPanel-v1.3.1-Setup.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware:  FrontPanelUSB-Win-Win4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware 64bit: FrontPanelUSB-Win-x4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
Bit files:&lt;br /&gt;
&lt;br /&gt;
3.1 Createc.bit&lt;br /&gt;
&lt;br /&gt;
2.5 stmafm2fifo.bit &lt;br /&gt;
&lt;br /&gt;
DLL's:&lt;br /&gt;
&lt;br /&gt;
Version 2  Okfrontpanel.dll&lt;br /&gt;
&lt;br /&gt;
Version3 32bit okfrontpanel32bitV3.dll&lt;br /&gt;
&lt;br /&gt;
Version3 64bit okfrontpanel64bit.dll&lt;br /&gt;
&lt;br /&gt;
In the initialization file stmafm.ini the flags:&lt;br /&gt;
&lt;br /&gt;
Enable_USB, FlashBoot, OpalKellyVer3 have to properly set to select a particular boot configuration.&lt;br /&gt;
&lt;br /&gt;
[[Category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation</id>
		<title>Hardware Driver Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation"/>
				<updated>2014-09-15T08:52:09Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The Createc Electronics is based on the SBC6711 DSP board manufactured by Innovative Integration.&lt;br /&gt;
&lt;br /&gt;
All communication between the SBC6711 and the PC is made via USB1.1.&lt;br /&gt;
&lt;br /&gt;
An FPGA addon board called  XEM3001 manufactured by OPAL Kelly provides a separate fast USB2.0 connection between PC and SBC6711.&lt;br /&gt;
&lt;br /&gt;
This board is optional under Windows XP but necessary to allow operation under Windows 7 (64bit), because no device driver for the SBC6711 is available under Windows 7.&lt;br /&gt;
&lt;br /&gt;
There are two basic operating modes of the SBC6711 board. In the first (default for WinXP) case the DSP program is downloaded via the USB 1.1 interface onto the SBC6711 during the initial boot process after power-on or reset every time the STMAFM software is started. In the second case the DSP program resides inside the Flash memory on the SBC6711 board. It is started directly from the board, i.e. no download is necessary. This second mode allows operating the SBC6711 without a device driver - a requirement for Windows 7 operation and an option for WinXP.&lt;br /&gt;
&lt;br /&gt;
Because of these two modes as well as of historic reasons different boot configurations exist and the correct drivers and dlls have to be supplied. The different operating modes can be set in the stmafm.ini. Please goto Tools --&amp;gt; Initialization and select the parameter HW_platform (0: No Board).&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 1. Windows XP, SBC6711 (HW-Platform: 1)&lt;br /&gt;
The SBC6711 driver has to be installed and the SBC6711.dll has to be in the program directory. The DSP program in the form of an *.out file resides also in the program directory. It is automatically extracted from the pstmafm.exe file when the program is started. The DSP boot file is supplied via USB1.1. The STM program will use USB1.1.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 2. Windows XP, SBC6711, XEM3001 (firmware 2.x)&lt;br /&gt;
Additionally the files okfrontpanel.dll and stmafm2fifo.bit have to be located in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 3. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additionally to 1. the files okfrontpanel32bitver3.dll and a createc.bit have to be in the program directory. The DSP boot file is supplied via USB1.1. The STM program will use USB2.0. The newer firmware in the XEM3001 is required for Windows 7 compatibility only.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 4. Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additional to 3. a *.bin file has to be flashed into onboard FlashROM using the programs Flash tools utility. The DSP will boot file is supplied via USB1.1. The STM program will use USB2.0.&lt;br /&gt;
&lt;br /&gt;
HW-Platform: 4. Windows 7/64bit, SBC6711, XEM3001 (firmware 3.x), Boot from on SBC6711 onboard flash&lt;br /&gt;
Identical to 4 only the XEM3001 driver for 64bit has to be installed, including the okfrontpanel64bit.dll.&lt;br /&gt;
&lt;br /&gt;
Remarks:&lt;br /&gt;
For new installs XEM3001 Firmware 3.x is recommended as it allows booting from Flash.&lt;br /&gt;
&lt;br /&gt;
The files:&lt;br /&gt;
&lt;br /&gt;
XEM3001 firmware files : &lt;br /&gt;
&lt;br /&gt;
Old Firmware:  Vers. 2.5    FrontPanel1-Legacy.FrmPkg&lt;br /&gt;
&lt;br /&gt;
Latest Firmware;  Vers. 3.1  FrontPanel3p1-Update.FrmPkg&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Frontpanel Software Installation:&lt;br /&gt;
&lt;br /&gt;
2.5 Firmware: FrontPanel-v1.3.1-Setup.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware:  FrontPanelUSB-Win-Win4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware 64bit: FrontPanelUSB-Win-x4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
Bit files:&lt;br /&gt;
&lt;br /&gt;
3.1 Createc.bit&lt;br /&gt;
&lt;br /&gt;
2.5 stmafm2fifo.bit &lt;br /&gt;
&lt;br /&gt;
DLL's:&lt;br /&gt;
&lt;br /&gt;
Version 2  Okfrontpanel.dll&lt;br /&gt;
&lt;br /&gt;
Version3 32bit okfrontpanle32bitV3.dll&lt;br /&gt;
&lt;br /&gt;
Version3 64bit okfrontpanel64bit.dll&lt;br /&gt;
&lt;br /&gt;
In the initialization file stmafm.ini the flags:&lt;br /&gt;
&lt;br /&gt;
Enable_USB, FlashBoot, OpalKellyVer3 have to properly set to select a particular boot configuration.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation</id>
		<title>Hardware Driver Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Hardware_Driver_Installation"/>
				<updated>2014-09-15T08:31:00Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The Createc Electronics is based on the SBC6711 DSP board manufactured by Innovative Integration.&lt;br /&gt;
&lt;br /&gt;
All communication between the SBC6711 and the PC is made via USB1.1.&lt;br /&gt;
&lt;br /&gt;
An FPGA addon board called  XEM3001 manufactured by OPAL Kelly provides a separate fast USB2.0 connection between PC and SBC6711.&lt;br /&gt;
&lt;br /&gt;
This board is optional under Windows XP but necessary to allow operation under Windows 7 (64bit), because no device driver for the SBC6711 is available under Windows 7.&lt;br /&gt;
&lt;br /&gt;
There are two basic operating modes of the SBC6711 board. In the first (default for WinXP) case the DSP program is downloaded via the USB 1.1 interface onto the SBC6711 during the initial boot process after power-on or reset every time the STMAFM software is started. In the second case the DSP program resides inside the Flash memory on the SBC6711 board. It is started directly from the board, i.e. no download is necessary. This second mode allows operating the SBC6711 without a device driver - a requirement for Windows 7 operation and an option for WinXP.&lt;br /&gt;
&lt;br /&gt;
Because of these two modes as well as of historic reasons different boot configurations exist and the correct drivers and dlls have to be supplied. The different operating modes can be set in the stmafm.ini. Please goto Tools --&amp;gt; Initialization and select the parameter &lt;br /&gt;
&lt;br /&gt;
1. Windows XP, SBC6711&lt;br /&gt;
The SBC6711 driver has to be installed and the SBC6711.dll has to be in the program directory. The DSP program in the form of an *.out file resides also in the program directory. It is automatically extracted from the pstmafm.exe file when the program is started.&lt;br /&gt;
&lt;br /&gt;
2.Windows XP, SBC6711, XEM3001 (firmware 2.x)&lt;br /&gt;
Additionally the okfrontpanel.dll and a stmafm2fifo.bit file has to be in the program directory.&lt;br /&gt;
&lt;br /&gt;
3.Windows XP, SBC6711, XEM3001 (firmware 3.x)&lt;br /&gt;
Additionally to 1. the okfrontpanel32bitver3.dll and a createc.bit file has to be in the program directory.&lt;br /&gt;
&lt;br /&gt;
4.Windows XP, SBC6711, XEM3001 (firmware 3.x), Boot from on SBC6711 onboard flash&lt;br /&gt;
Additional to 3. a *.bin file has to be flashed into onboard FlashROM using the programs Flash tools utility&lt;br /&gt;
&lt;br /&gt;
5. Windows 7/64bit, SBC6711, XEM3001 (firmware 3.x), Boot from on SBC6711 onboard flash&lt;br /&gt;
Identical to 4 only the XEM3001 driver for 64bit has to be installed, including the okfrontpanel64bit.dll.&lt;br /&gt;
&lt;br /&gt;
Remarks:&lt;br /&gt;
For new installs XEM3001 Firmware 3.x is recommended as it allows booting from Flash.&lt;br /&gt;
&lt;br /&gt;
The files:&lt;br /&gt;
&lt;br /&gt;
XEM3001 firmware files : &lt;br /&gt;
&lt;br /&gt;
Old Firmware:  Vers. 2.5    FrontPanel1-Legacy.FrmPkg&lt;br /&gt;
&lt;br /&gt;
Latest Firmware;  Vers. 3.1  FrontPanel3p1-Update.FrmPkg&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Frontpanel Software Installation:&lt;br /&gt;
&lt;br /&gt;
2.5 Firmware: FrontPanel-v1.3.1-Setup.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware:  FrontPanelUSB-Win-Win4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
3.1 Firmware 64bit: FrontPanelUSB-Win-x4.0.0.exe&lt;br /&gt;
&lt;br /&gt;
Bit files:&lt;br /&gt;
&lt;br /&gt;
3.1 Createc.bit&lt;br /&gt;
&lt;br /&gt;
2.5 stmafm2fifo.bit &lt;br /&gt;
&lt;br /&gt;
DLL's:&lt;br /&gt;
&lt;br /&gt;
Version 2  Okfrontpanel.dll&lt;br /&gt;
&lt;br /&gt;
Version3 32bit okfrontpanle32bitV3.dll&lt;br /&gt;
&lt;br /&gt;
Version3 64bit okfrontpanel64bit.dll&lt;br /&gt;
&lt;br /&gt;
In the initialization file stmafm.ini the flags:&lt;br /&gt;
&lt;br /&gt;
Enable_USB, FlashBoot, OpalKellyVer3 have to properly set to select a particular boot configuration.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Installation</id>
		<title>Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Installation"/>
				<updated>2014-09-15T08:05:37Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: /* First Steps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Installation ==&lt;br /&gt;
&lt;br /&gt;
1.Installation of the STMAFM Software package and the required Hardware&lt;br /&gt;
&lt;br /&gt;
The STMAFM - Software package uses the digital signal processor (DSP) board SBC6711 (150MHz/250MHz) from Innovative Integration ( www.innovative-dsp.com ). The SBC6711 is connected to the PC by a standard USB 1.1 cable. Optionally a high speed USB 2.0 FPGA adapter board is available. The drivers for the SBC6711 available from Innovative Integration support Windows 2000/XP. Support for Windows 7 is available through the optional USB 2.0 FPGA adapter board only. A single Createc ADDA board (6ch 20bit DA, 4ch 18bit AD)  is used by the software in the standard configuration. A second board can be optionally installed for AFM operation (PLL) or just to double the available number of ADC's and DAC's. Also another 4 channel 16bit DAC board can be attached to each standard ADDA board. &lt;br /&gt;
&lt;br /&gt;
The STMAFM-Program can be operated together with the DSP-board for Data Acquisition, but also without the board for Data Analysis. In the latter case no driver installation is needed. Several instants of the STMAFM-Program can be run simultaneously on the same computer, but only one will startup in Data Acquisition mode. The program running in Data Acquisition mode will inform the other programs if new data has been acquired and saved.&lt;br /&gt;
&lt;br /&gt;
1.1  How to install the hardware:&lt;br /&gt;
Switch on the DSP electronics box before (!) connecting the USB cable from the electronics to the USB input of a PC. The first time hardware installation is described here.&lt;br /&gt;
&lt;br /&gt;
1.2  How to install the software:&lt;br /&gt;
&lt;br /&gt;
To deinstall an older version of the software go to Settings&amp;gt;Control Panel&amp;gt;Software and remove the STMAFM software. &lt;br /&gt;
To install a new full release, please copy the Setup.exe file to a temporary directory and start the file. Follow the instructions on the screen of the standard Installshield procedure.&lt;br /&gt;
&lt;br /&gt;
== First Steps ==&lt;br /&gt;
&lt;br /&gt;
Basic Structure of the Software&lt;br /&gt;
&lt;br /&gt;
The software consists of several windows. The main window STMAFM contains all necessary control elements to for data acquisition and image analysis. The software is controlled by set of parameters which can be accessed through the form (window) called 'Parameter'. On several panels all important parameters can be adjusted. Additional windows for lateral and vertical manipulation, I/V spectroscopy, data recording, coarse approach control, 3d rendering etc are available. On startup the software tries to access the Createc DSP Electronic, which needs to be switched on and connected beforehand. If the electronics can not be found the software starts up in analysis mode. &lt;br /&gt;
&lt;br /&gt;
Several instances of the software can be run at the same time, but only the first one will be in Data Acqusition mode. It is usually good to start up two instances of the software. The first for data acquisition, and a second for data analysis. This is supported by a communication channel which is setup between all instances. Newly acquired and saved images will be automatically communicated to other instances on the computer.&lt;br /&gt;
&lt;br /&gt;
1. First steps&lt;br /&gt;
To learn about the different features of the STMAFM program load a test file A....dat. from the file menu. &lt;br /&gt;
Test the different kinds of image processing and analysis using this file. Most of the features are almost self explaining, but will be discussed later in this manual. &lt;br /&gt;
&lt;br /&gt;
2. How to take an image&lt;br /&gt;
Start the STMAFM-Program. Select the image size, the scan area and scan speed on the 'SCAN' panel in the Parameter window.&lt;br /&gt;
&lt;br /&gt;
Start the scan by pressing the &amp;lt;Start&amp;gt; - button.&lt;br /&gt;
&lt;br /&gt;
When the scan is finished, click on the &amp;lt;QSave&amp;gt; - button to save the scan in the current directory.&lt;br /&gt;
&lt;br /&gt;
[[category:stmafm_manual]]&lt;/div&gt;</summary>
		<author><name>Zoephel</name></author>	</entry>

	<entry>
		<id>http://spm-wiki.createc.de/index.php?title=Installation</id>
		<title>Installation</title>
		<link rel="alternate" type="text/html" href="http://spm-wiki.createc.de/index.php?title=Installation"/>
				<updated>2014-09-15T07:58:06Z</updated>
		
		<summary type="html">&lt;p&gt;Zoephel: /* Installation */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Installation ==&lt;br /&gt;
&lt;br /&gt;
1.Installation of the STMAFM Software package and the required Hardware&lt;br /&gt;
&lt;br /&gt;
The STMAFM - Software package uses the digital signal processor (DSP) board SBC6711 (150MHz/250MHz) from Innovative Integration ( www.innovative-dsp.com ). The SBC6711 is connected to the PC by a standard USB 1.1 cable. Optionally a high speed USB 2.0 FPGA adapter board is available. The drivers for the SBC6711 available from Innovative Integration support Windows 2000/XP. Support for Windows 7 is available through the optional USB 2.0 FPGA adapter board only. A single Createc ADDA board (6ch 20bit DA, 4ch 18bit AD)  is used by the software in the standard configuration. A second board can be optionally installed for AFM operation (PLL) or just to double the available number of ADC's and DAC's. Also another 4 channel 16bit DAC board can be attached to each standard ADDA board. &lt;br /&gt;
&lt;br /&gt;
The STMAFM-Program can be operated together with the DSP-board for Data Acquisition, but also without the board for Data Analysis. In the latter case no driver installation is needed. Several instants of the STMAFM-Program can be run simultaneously on the same computer, but only one will startup in Data Acquisition mode. The program running in Data Acquisition mode will inform the other programs if new data has been acquired and saved.&lt;br /&gt;
&lt;br /&gt;
1.1  How to install the hardware:&lt;br /&gt;
Switch on the DSP electronics box before (!) connecting the USB cable from the electronics to the USB input of a PC. The first time hardware installation is described here.&lt;br /&gt;
&lt;br /&gt;
1.2  How to install the software:&lt;br /&gt;
&lt;br /&gt;
To deinstall an older version of the software go to Settings&amp;gt;Control Panel&amp;gt;Software and remove the STMAFM software. &lt;br /&gt;
To install a new full release, please copy the Setup.exe file to a temporary directory and start the file. Follow the instructions on the screen of the standard Installshield procedure.&lt;br /&gt;
&lt;br /&gt;
== First Steps ==&lt;br /&gt;
&lt;br /&gt;
Basic Structure of the Software&lt;br /&gt;
&lt;br /&gt;
The software consists of several windows. The main window STMAFM contains all necessary control elements to for data acquisition and image analysis. The software is controlled by set of parametes which can be accesses through the window called 'Parameter'. On several panels all important parameters can be adjusted. Additional windows for lateral and vertical manipulation, I/V spectroscopy, data recording, coarse approach control, 3d rendering etc are available. On startup the software tries to access the Createc DSP Electronic, which should be connected by USB. If the electronics can not be found the software starts up in analysis mode. &lt;br /&gt;
&lt;br /&gt;
Several instances of the software can be run at the same time, but only one will be in Data Acqusition mode. It is usually good to start up two instances of the software. One for data acquisition, and a second for Data Analysis. This is supported by a communication channel which is setup between all instances. New acquired and saved images will be automatically communicated to other instances on the computer.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
1. First steps:&lt;br /&gt;
To learn about the different features of the STMAFM program load a test file A....dat. from the file menu. &lt;br /&gt;
Test the different kinds of image processing and analysis use this file. Most of the features are almost self explaning, but will be discussed later in this manual. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2. How to take an image&lt;br /&gt;
Start the STMAFM-Program. Select the image size, the scan area and scan speed on the 'SCAN' panel in the Parameter window.&lt;br /&gt;
&lt;br /&gt;
Start the Scan by pressing the &amp;lt;Start&amp;gt; - Button.&lt;br /&gt;
&lt;br /&gt;
When the scan is finished, click on the &amp;lt;QSave&amp;gt; - Button to save the Scan in the current directory.&lt;br /&gt;
&lt;br /&gt;
[[category:stmafm_manual]]&lt;/div&gt;</summary>